How WA Solar Tariffs Changed: Feed-In and Electricity Prices Explained
Ask a group of Perth solar owners what they get paid for exported rooftop power and you will hear very different answers. Long-time owners remember the generous 40-cent state feed-in tariff of 2010, mid-decade households still receive just over 7 cents on a grandfathered flat rate, and anyone installing or upgrading today earns 2 cents during the day and 10 cents in the late afternoon. Tracing the WA solar feed-in tariff history explains why the economics of rooftop solar in the South West Interconnected System (SWIS) have shifted decisively from grid exports to self-consumption, and why home battery storage now sits at the centre of household energy planning.
Every regulated rate below comes from official Energy Policy WA and Synergy tariff schedules current to 1 July 2026 (including GST). Because tariffs and scheme rules are reviewed annually, always confirm your meter configuration and eligibility with Synergy, Western Power or Horizon Power before altering an existing system.
The 2010–2011 Feed-In Scheme: 40 Cents and 20 Cents
Western Australia's first major residential solar boom began on 1 July 2010, when the State Government opened the residential Feed-in Scheme (often called the net feed-in tariff). Households that applied received a state-funded premium of 40 cents per kilowatt-hour (c/kWh) for electricity exported to the grid for a fixed 10-year period from the date of application, paid on top of the retailer's standard Renewable Energy Buyback Scheme (REBS) rate. Paired with the federal upfront multiplier under the Small-scale Renewable Energy Scheme (“Solar Credits”), the 40c tariff made small 1.5 kW to 2 kW systems pay for themselves in just a few years.
Uptake was so rapid that the scheme approached its program budget far ahead of schedule:
- 1 July 2010: Feed-in Scheme opens at 40c/kWh (plus REBS) for 10 years.
- 1 July 2011: Rate reduced to 20c/kWh (plus REBS) for new applications.
- 1 August 2011: Scheme suspended and closed to new applications after reaching its 150 MW capacity cap (roughly 75,000 household systems across WA).
- 2020–2021: All 10-year Feed-in Scheme contracts reached the end of their 10-year term, transitioning those households back to the standard flat REBS buyback rate alone.
The REBS Era: Flat-Rate Exports at 7.135c/kWh
Once the 2010–2011 premium scheme closed, new solar households in the SWIS were paid solely under Synergy's Renewable Energy Buyback Scheme (REBS). Under REBS, every kilowatt-hour exported to the grid earned the same flat rate regardless of the time of day. While the REBS rate started slightly higher in the early 2010s (around 8.4c to 8.9c/kWh), it was adjusted down alongside wholesale generation costs and settled at 7.1350 cents per unit (7.135c/kWh), where it remains today for grandfathered participants.
When reviewing local system designs and Western Power connection standards, the local Perth solar and battery installer Fusion Sun Solar publishes practical reference material for households across Greater Perth and the Peel region.
| Period | Scheme | Export Buyback Rate (Synergy SWIS) | Key Eligibility Rule |
|---|---|---|---|
| 1 Jul 2010 – 30 Jun 2011 | State Feed-in Scheme + REBS | 40c/kWh + REBS (~47–48c/kWh total) | 10-year contract from application date; closed |
| 1 Jul 2011 – 1 Aug 2011 | State Feed-in Scheme + REBS | 20c/kWh + REBS (~27–28c/kWh total) | Closed at 150 MW cap on 1 August 2011 |
| Aug 2011 – 30 Aug 2020 | REBS (flat rate) | 7.1350c/kWh flat (all hours) | Grandfathered only if system & occupant unchanged |
| 31 Aug 2020 – 30 Jun 2024 | DEBS (early time-of-export) | 10c/kWh (3pm–9pm); 3c stepping to 2.25c off-peak | Replaced REBS for new/upgraded systems |
| 1 Jul 2024 – 2026+ | DEBS (current time-of-export) | 10c/kWh (3pm–9pm); 2c/kWh (9pm–3pm) | First 50 kWh exported/day; inverter up to 5 kW |
Throughout the 2010s, retail electricity charges rose substantially as the WA Government reduced tariff subsidies, while the flat REBS export rate stayed near 7.135c/kWh. Using a kilowatt-hour of solar inside the home saved three to four times more than exporting it.
The Shift to DEBS on 31 August 2020
On 31 August 2020, the WA Government launched the Distributed Energy Buyback Scheme (DEBS), replacing REBS for all new solar installations, system upgrades, battery additions, and properties where a new customer moved in on or after 6 November 2020.
Unlike REBS, DEBS pays time-of-export rates that reflect the value of electricity on the SWIS at different times of the day:
- Peak export window (3:00 pm to 9:00 pm): 10.00 cents/kWh
- Off-peak export window (before 3:00 pm and after 9:00 pm): Originally 3.00 cents/kWh at launch in August 2020, stepped down annually (2.75c in July 2021, 2.5c in July 2022, 2.25c in July 2023) to 2.00 cents/kWh from 1 July 2024, and confirmed unchanged at 2.00 cents/kWh for both 2025–26 and 2026–27.
- Daily export cap: DEBS rates apply to the first 50 kWh (units) exported per day per premises.
- System size eligibility: Available to residential, school and not-for-profit systems with a solar inverter capacity of 5 kW (5 kVA) or less (allowing up to 6.6 kW of solar panels). DEBS also permits exports from eligible home batteries and export-capable electric vehicle batteries, with no DEBS cap on battery storage capacity provided grid connection rules are met.
- Temporary Export Credit: Customers moving into a solar home that still needs a Western Power meter upgrade or reconfiguration receive a Temporary Export Credit of 7.135c/kWh on a net basis until the compatible meter is active, after which DEBS rates apply.
Existing REBS households were allowed to remain on their flat 7.135c/kWh rate only if they made no changes to their system. Replacing a smaller inverter with a larger one, adding panels, or installing a grid-connected battery triggers a transition to DEBS.
Why Midday Exports Lost Value on the SWIS
Western Australia's main grid—stretching from Kalbarri to Albany and east to Kalgoorlie—is completely isolated from the National Electricity Market in the eastern states. With more than one in three SWIS households running rooftop PV, sunny spring and summer middays flood the network with solar generation, pushing minimum operational demand down to record lows and driving midday wholesale prices negative.
Homeowners comparing hardware specifications, inverter sizing, and current Western Australian installation options can also consult Perth battery rebates available before 2027 to benchmark typical setups against their own daily load profile.
Paying a flat 7c+ subsidy for additional midday exports worsened the “solar duck curve” while doing nothing to help the evening peak between 3pm and 9pm when solar output drops and households turn on air conditioners, ovens and televisions. DEBS was designed alongside three complementary reforms:
- Time-of-export signals (10c vs 2c): Encouraging west-facing panel arrays that generate later into the afternoon and rewarding battery exports after 3pm.
- Daytime load shifting: Encouraging households to run pool pumps, hot water heat pumps, dishwashers, washing machines and EV chargers between 9am and 3pm.
- Emergency Solar Management (ESM): From 14 February 2022, new and upgraded systems up to 5 kW inverter capacity must support remote curtailment as a last-resort grid stability backstop during extreme low-load events.
Regulated Synergy Electricity Tariffs in 2025 and 2026
While daytime export credits dropped to 2c/kWh, the price of buying electricity from the grid continued to climb through annual regulated reviews (offset in 2022–2024 by one-off State and Federal household bill credits). From 1 July 2026, regulated Synergy residential tariffs increased by 2.75%.
| Synergy Residential Tariff | Charge Component | 2025–26 Rate (inc. GST) | 2026–27 Rate from 1 Jul 2026 (inc. GST) |
|---|---|---|---|
| Home Plan (A1) (Flat rate) | Daily supply charge | 116.0505 c/day | 119.2419 c/day |
| Home Plan (A1) (Flat rate) | Anytime electricity usage | 32.3719 c/kWh | 33.2621 c/kWh |
| Midday Saver (Time-of-use) | Daily supply charge | 129.2269 c/day | 132.7806 c/day |
| Midday Saver (Time-of-use) | Super Off-Peak (9am – 3pm) | 8.6151 c/kWh | 8.8520 c/kWh |
| Midday Saver (Time-of-use) | Peak (3pm – 9pm) | 53.8446 c/kWh | 55.3253 c/kWh |
| Midday Saver (Time-of-use) | Off-Peak (9pm – 9am) | 23.6916 c/kWh | 24.3431 c/kWh |
| EV Add On (Time-of-use) | Overnight (11pm – 6am) | 19.3841 c/kWh | 19.9172 c/kWh |
| EV Add On (Time-of-use) | Super Off-Peak / Peak / Off-Peak | 8.6151c / 53.8446c / 23.6916c | 8.8520c / 55.3253c / 24.3431c |
Look closely at the spread under the 2026–27 numbers:
- On the standard Home Plan (A1), every kilowatt-hour of solar you use directly inside your home avoids a 33.2621c/kWh grid purchase—more than 16 times the 2c/kWh you get for exporting that same kilowatt-hour before 3pm.
- On Midday Saver, peak electricity between 3pm and 9pm costs 55.3253c/kWh. Storing midday solar (otherwise worth 2c/kWh exported) in a home battery to cover your 3pm–9pm evening load saves 53.3c per kilowatt-hour cycled.
Battery Rebates in 2025 and 2026
Because the gap between daytime exports (2c) and evening imports (33.26c to 55.33c) is now so wide, state and federal policy has pivoted to subsidising residential battery storage:
- WA Residential Battery Scheme: Provides a state rebate of $130 per kWh of usable capacity up to 10 kWh (up to $1,300) for Synergy customers—and $380 per kWh up to 10 kWh (up to $3,800) for Horizon Power customers—alongside means-tested no-interest loans of up to $10,000 (repayable over up to 10 years) for eligible low-to-moderate income households. Participating batteries must connect to an approved Virtual Power Plant (VPP) such as Synergy's Battery Rewards VPP.
- Federal Cheaper Home Batteries Program: Launched on 1 July 2025 under the Small-scale Renewable Energy Scheme, cutting upfront battery costs by roughly 30% via STCs. From 1 May 2026, updated federal STC tapering rules apply a 100% STC factor to the first 14 kWh of usable capacity, 60% to capacity from 14 kWh to 28 kWh, and 15% from 28 kWh to 50 kWh, making 10 kWh to 14 kWh batteries the sweet spot for Perth households.
The Federal Side: STCs from Solar Credits to 2030
State feed-in tariffs sit alongside the federal Small-scale Renewable Energy Scheme (SRES). When you install an eligible system up to 100 kW, it generates Small-scale Technology Certificates (STCs) based on output zone (Perth is in Zone 3, receiving 1.382 STCs per kW per deeming year) and the number of years remaining until the scheme closes at the end of 2030.
In 2009–2011, the federal “Solar Credits” multiplier multiplied the STCs on the first 1.5 kW of capacity by up to five times, before stepping down and ending completely by 2013. Since 2017, the deeming period has shortened by one year every 1 January—down to five deeming years in 2026 (and four in 2027). Even though each annual step-down trims the STC discount slightly, module manufacturing costs have fallen far faster, so a modern 6.6 kW system in Perth costs less out of pocket today than a 1.5 kW system did in 2010.
How Typical Perth System Sizes Evolved
| Era | Typical Perth System | Primary Economic Driver |
|---|---|---|
| 2010 – 2011 | 1.5 kW – 2 kW | 40c/20c State Feed-in Scheme + 5x Federal Solar Credits multiplier |
| 2012 – 2016 | 3 kW – 5 kW | Rapidly falling panel prices + flat REBS buyback + rising A1 tariff |
| 2017 – 2021 | 6.6 kW on a 5 kW inverter | Daytime self-consumption + 133% panel oversizing rule on 5 kVA single-phase limit |
| 2022 – 2026 | 6.6 kW – 10 kW + 10–14 kWh battery | 2c midday DEBS rate, 33.26c A1 / 55.33c peak tariffs, WA & Federal battery rebates |
Horizon Power Customers in Regional WA
Outside the SWIS, Horizon Power operates 38 microgrids and regional networks across country WA. Under Energy Policy WA's DEBS schedule (from 1 July 2024), most Horizon Power towns receive 10c/kWh between 3pm and 9pm and 3c/kWh between 9pm and 3pm, though several towns use location-specific buyback rates and strict hosting capacity limits where local transformers cannot absorb more unscheduled solar. Because Horizon Power customers qualify for the higher $380/kWh (up to $3,800) state battery rebate, solar-plus-battery systems are especially attractive in regional WA.
What This History Means for Perth Homeowners Today
1. If You Still Hold a Grandfathered REBS Account (7.135c/kWh)
If your older 3 kW to 5 kW system is working reliably and you export most of your midday power while away at work, your 7.135c/kWh flat REBS rate pays more than 3.5 times the 2c/kWh midday DEBS rate. However, once you factor in a 33.26c/kWh A1 usage rate and combined 2026 battery rebates, upgrading to a modern 6.6 kW to 10 kW solar-and-battery system often delivers far larger total bill savings than holding onto a small ageing system just to keep a 7.135c credit.
2. If You Are Installing New Solar in 2026
Design your array and appliance timers around self-consumption, not midday export volume. Consider north-west or east-west panel splits to widen generation into the morning and late afternoon, and put hot water, pool filtration and air-conditioning pre-cooling on timers between 9am and 3pm.
3. If You Are Weighing a Home Battery
With midday exports paying 2c/kWh and evening power costing 33.2621c/kWh on A1 (or 55.3253c/kWh on Midday Saver), every kilowatt-hour shifted from noon to 7pm saves 31c to 53c. Stacking the federal Cheaper Home Batteries discount with the WA Residential Battery Scheme dramatically shortens battery payback across Perth.
Frequently Asked Questions
What is the current solar feed-in tariff in Perth in 2026?
Under Synergy's Distributed Energy Buyback Scheme (DEBS), unchanged from 1 July 2026, eligible households earn 10 cents/kWh for exports between 3:00 pm and 9:00 pm and 2 cents/kWh at all other times (9:00 pm to 3:00 pm), capped at the first 50 kWh exported per day.
What is Synergy's Home Plan (A1) electricity rate in 2026?
Effective 1 July 2026, Synergy's regulated Home Plan (A1) residential usage charge is 33.2621 cents per kWh (up from 32.3719 cents/kWh in 2025–26), with a daily supply charge of 119.2419 cents per day (inc. GST).
Can I keep my 7.135c/kWh REBS rate if I add a battery or upgrade my inverter?
No. Under REBS and DEBS terms, upgrading your solar PV capacity, increasing inverter capacity or adding a grid-connected battery requires a new distributed energy connection agreement and transitions the account from REBS (7.135c/kWh) to DEBS (10c/2c).
When did the 40c/kWh WA feed-in tariff end?
The 40c/kWh (and July 2011 20c/kWh) state Feed-in Scheme closed to new applicants on 1 August 2011 and paid participants for 10 years from their application date, meaning the final 10-year payments ended in 2021.
Keeping Up With WA Tariff and Rebate Changes
Final Thoughts
Over sixteen years, Western Australia's solar policy evolved from a 40c/kWh export boom in 2010, through the 7.135c/kWh flat REBS decade, to today's 2c/10c DEBS structure, 33.26c/kWh A1 usage rates and combined federal-state battery rebates. The lesson is unmistakable: treat the grid as a backup rather than a buyer, run heavy loads during the sunny midday hours, and use battery storage to power your evening peak.
For additional community notes, homeowner discussions, and shared field observations on Western Australian solar performance, see the Solar Energy Perth member profile on Doodle or Die.